T-D13 Distribution Transformer Low Voltage Substation Bushing Isolation Protective Cover

Distribution transformer low voltage bushing protection coverSubstation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth. Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in terms of damage to equipment, reduced reliability and in some

Featured Products


Distribution transformer low voltage bushing protection cover
T-D13 Distribution Transformer Low Voltage Substation Bushing Isolation Protection Cover
T-D13 Distribution Transformer Low Voltage Substation Bushing Isolation Protection Cover

Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth. Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in terms of damage to equipment, reduced reliability and in some cases even electrocution of protected species.
Almost any event of this nature can be prevented by insulating the strategically vulnerable bare metalwork with a combination of the isolation protection covers.
Substation buhsing isolation protection covers made by United Electric are designed to protect the electrical connections from animals and corrosion and unexpected touch etc., to make electricity using in saver way.



Feature
 Easy and simple installation, tool free application, long service life.
 Covers are held in place with UV-stabilized plastic nuts and bolts, be easily removed for maintenance.
 Excellent UV and weather resistance, anti-tracking and wear resistance.
 Excellent pollution resistance and hydrophobic performance.
 Standard color: Red. Other colors are available upon to request.

 
Material test data
 
Property Test method Typical data
Tensile strength ASTM D 2671 ≥12MPa
Tensile strength after aging ASTM D 2671 (120°C /168hrs) ≥10MPa
Elongation at break ASTM D 2671 ≥400%
Elongation at break after aging ASTM D 2671 (120°C /168hrs) ≥300%
Dielectric strength IEC 243 ≥12kV/mm
Volume resistance IEC 93 ≥1012Ω.cm
Flammability IEC 60684-2 Method C 60sec max.
Low temperature flexibility ASTM D 2671 -40°C, 4hrs, no cracking
Water absirption ISO 62 (23°C /14days) <0.5%


Electrical test data
 
Test item Test method Test result
Fault connection of other articles Applied voltage 21kV
loading time 1min
leakage current ≤2 mA
Pass
Leakage current ≤2 mA Pass



T-D13 Distribution Transformer Low Voltage Substation Bushing Isolation Protection CoverT-D13 Distribution Transformer Low Voltage Substation Bushing Isolation Protection CoverT-D13 Distribution Transformer Low Voltage Substation Bushing Isolation Protection Cover
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours