2 Wire Loop Powered 4-20mA 0-20mA Input and output Isolator
4-20mA Loop Powered Converter Featrures:
-Low cost, small size, standard SIP12 package
-Electromagnetic Isolation
-Signal input/output, 3000VDC isolated voltage
-No external instrument needed for power supply
-4-20mA high accuracy of current input/output(distortion<0.2%)
-Industrial temperature(-45~+85 centigrade)
-High linearity(Nonlinearity<0.2%)
-Small signal bandwidth: 50Hz
-Weld to PCB directly, SIP12 Package
4-20mA Loop Powered Converter Applications:
-Analog signal data acquisition and isolation
-Isolated 4-20mA signal transmission
-Industrial process signal isolation
-Ground-loop elimination
-No distortion in long distance signal transmission
-Instrument signal acquisition
-Electric supervision and medical application
-Isolated safe bar
-Biomedical measurements.
4-20mA Loop Powered Converter Parameters:
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/d3b9c125bdb7bfd708afa26df6b2b51f.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/8341f8275ad1bc86c69190699b41aaee.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/e503b1f2b7596c4f1b60367648f3bbc7.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/d23b97697a657318f516484718b21c6e.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/10e7b3d03add3dd818e92967f914eeba.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/79408716fbcfe3841cf4a61b6b142e17.webp)
4-20mA Loop Powered Converter Featrures:
-Low cost, small size, standard SIP12 package
-Electromagnetic Isolation
-Signal input/output, 3000VDC isolated voltage
-No external instrument needed for power supply
-4-20mA high accuracy of current input/output(distortion<0.2%)
-Industrial temperature(-45~+85 centigrade)
-High linearity(Nonlinearity<0.2%)
-Small signal bandwidth: 50Hz
-Weld to PCB directly, SIP12 Package
4-20mA Loop Powered Converter Applications:
-Analog signal data acquisition and isolation
-Isolated 4-20mA signal transmission
-Industrial process signal isolation
-Ground-loop elimination
-No distortion in long distance signal transmission
-Instrument signal acquisition
-Electric supervision and medical application
-Isolated safe bar
-Biomedical measurements.
4-20mA Loop Powered Converter Parameters:
Signal Input | Signal output | Assistant Power Supply | Power Consumption | Isolation | Accuracy (%) | Temperature Drift | Operating Temperature | Non- Linearity (%) | Frequency Response |
4-20mA 0-20mA | 4-20mA 0-20mA | 8-32V | -- | 3000VDC | 0.1 0.2 0.5 | 100 | -45-+85º C | less than 0.2 | more than 100Hz |
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/d3b9c125bdb7bfd708afa26df6b2b51f.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/8341f8275ad1bc86c69190699b41aaee.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/e503b1f2b7596c4f1b60367648f3bbc7.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/d23b97697a657318f516484718b21c6e.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/10e7b3d03add3dd818e92967f914eeba.webp)
![4-20mA Isolator 4-20mA Current Loop Isolator](https://img2.grofrom.com/guiaseis/79408716fbcfe3841cf4a61b6b142e17.webp)