35kv high voltage busbar insulator; fiber heat shrinkable tube

35KV high voltage busbar insulator; optic fiber heat shrink tubeModel Number: SB-WMPG SERIES Working temperature: -55ºC ~ 125ºCShrink ratio: 2:1 (1kV&35kV) & 2.5:1 (10kV)StructureBus-bar heat shrinkable protection tube adopts cross-linked and environmental friendly polyolefin material. It restric

Featured Products

35KV high voltage busbar insulator; optic fiber heat shrink tube
Model Number: SB-WMPG SERIES 
Working temperature: -55ºC ~ 125ºC
Shrink ratio: 2:1 (1kV&35kV) & 2.5:1 (10kV)
Structure
Bus-bar heat shrinkable protection tube adopts cross-linked and environmental friendly polyolefin material. It restricts the hazardous substance in PBB, PBBD, PBBE and other heavy metal, and supplies high dielectric strength and voltage withstand performance. It prevents bus-bar from chemical corrosion effected by strong acid, alkali, salt etc. It also has environmental friendly, flexible, flame retardant, soft performance.
Usage

It is mainly used in dielectric and mechanical protection, joints and terminals.
Characteristics
1.
Shrink temperature: 84ºC ~ 125ºC
2.Environmental, flexible, flame retardant, soft

Standards
1) GB/T 1059-2007                     2) RoHS approval
35kv High Voltage Busbar Insulator; Optic Fiber Heat Shrink Tube
35kv High Voltage Busbar Insulator; Optic Fiber Heat Shrink Tube
35kv High Voltage Busbar Insulator; Optic Fiber Heat Shrink Tube
35kv High Voltage Busbar Insulator; Optic Fiber Heat Shrink Tube

Specification
 

PropertyUnitStandardTest Method
Tensile StrengthMPA≥10.4(before aging)GB/T 1040
130ºC *168hrs
≥7.3(after aging)
Elongation%≥300(before aging)GB/T 1040; GB/T7141
130ºC*168hrs
      ≥100(after aging)
Heat Shock-no sticking; no crackingJB 7829appendixD.(160ºC*4hrs)
Cold Blend-no cracking-30ºC*4hrs
Breakdown StrengthKV/mm≥25GB/T 1408.1
Volume ResistivityΩ. cm≥1×1014GB/T 1410
Longitudinal Change%≥50 
Off-center%≤30UL 224
Flame Retardant-≥30GD/T 2406
Water Absorption%≤0.5ISO 62-1980
Dielectric WithstandKV/mm≥30kV.1minGB/T 1408.1
Shore Hardness(Shore A) ≤90GB 2401

*This data is suitable for 10kv bus bar protection tube. When managing this test, the user must make the tube recovery evenly and make sure the max thickness>2mm, and bus-bar tubes are longer than 1200mm.**35kV bus bar off center proportion≤50%.
Dimension
1KV Bus Bar Protection Heat Shrinkable Tube
 

SpecificationBus Bar Width(mm)As Supplied(mm)After Recovery(mm)Standard Package
IDWall ThicknessID  Wall Thickness       (m/roll)
1KV WMPG 303031.5±1.00.50±0.15≤15.01.00±0.1550
1KV WMPG 353536.5±1.00.50±0.15≤17.51.00±0.1550
1KV WMPG 404041.5±1.00.55±0.15≤20.01.00±0.1550
1KV WMPG 454546.5±1.00.55±0.15≤22.51.00±0.1525
1KV WMPG 5050≥500.55±0.15≤25.01.10±0.1525
1KV WMPG 6060≥600.60±0.15≤30.01.20±0.1525
1KV WMPG 7070≥700.65±0.15≤35.01.30±0.2025
1KV WMPG 75*75≥750.65±0.15≤38.01.30±0.2025
1KV WMPG 8080/100≥800.65±0.15≤40.01.30±0.2025
1KV WMPG 85*80/100≥850.65±0.15≤43.01.30±0.2025
1KV WMPG 90100≥900.65±0.15≤45.01.30±0.2025
1KV WMPG 100100/120≥1000.65±0.20≤50.01.30±0.2025
1KV WMPG 120150≥1200.65±0.20≤60.01.30±0.2025
1KV WMPG 150180≥1500.65±0.20≤70.01.30±0.2025
1KV WMPG 180MAX≥1800.65±0.30≤90.01.30±0.3025
1KV WMPG 210*MAX≥2100.65±0.30≤105.01.30±0.3025
1KV WMPG 230*MAX≥2300.65±0.30≤115.01.30±0.3025
1KV WMPG 250*MAX≥2500.65±0.30≤125.01.30±0.3025
 
  1. 10KV Bus Bar Protection Heat Shrinkable Tube
SpecificationBus Bar Width(mm)As Supplied(mm)After Recovery(mm)Standard Package
IDWall ThicknessIDWall Thickness(m/roll)
10KV WMPG 15/615/12≥151.0±0.30≤6.02.5±0.2025
10KV WMPG 20/820/15≥201.0±0.30≤8.02.5±0.2025
10KV WMPG 25/1025/18≥251.0±0.30≤10.02.5±0.2025
10KV WMPG 30/1230/20≥301.0±0.30≤12.02.5±0.2025
10KV WMPG 40/1640/30≥401.2±0.30≤16.02.8±0.3025
10KV WMPG 50/2050/35≥501.2±0.30≤20.02.8±0.3025
10KV WMPG 60/2460/45≥601.2±0.30≤24.02.8±0.3025
10KV WMPG 65/26*65/45≥651.2±0.30≤26.02.8±0.3025
10KV WMPG 70/2870/50≥701.2±0.30≤28.02.8±0.3025
10KV WMPG 75/30*75/50≥751.2±0.30≤30.02.8±0.3025
10KV WMPG 80/3280/55≥801.2±0.30≤32.02.8±0.3025
10KV WMPG 85/34*80/65≥851.2±0.30≤34.02.8±0.3025
10KV WMPG 100/40100/75≥1001.2±0.30≤40.02.8±0.3025
10KV WMPG 120/48120/85≥1201.2±0.30≤48.02.8±0.3025
10KV WMPG 150/60150/105≥1501.2±0.30≤60.02.8±0.3025
10KV WMPG 180/72180/120≥1801.2±0.30≤72.02.8±0.3025
10KV WMPG 210/84*210/140≥2101.2±0.40≤84.02.8±0.3025
10KV WMPG 230/92*230/150≥2301.2±0.40≤92.02.8±0.3025
10KV WMPG 250/100*250/160≥2501.2±0.40≤100.02.8±0.3025
  1. 35 KV Bus Bar Protection Heat Shrinkable Tube
SpecificationBus Bar Width (mm)As Supplied(mm)After Recovery(mm)Standard Package
IDWall ThicknessIDWall Thickness(m/roll)
35KV WMPG 30/1530≥302.0±0.60≤15.04.0±0.3015
35KV WMPG 35/1830/40≥352.0±0.60≤17.54.0±0.3015
35KV WMPG 40/2040≥402.0±0.60≤20.04.0±0.3015
35KV WMPG 50/2550≥502.0±0.60≤25.04.0±0.3015
35KV WMPG 60/3060≥602.0±0.60≤30.04.0±0.3015
35KV WMPG 65/33*60/70≥652.0±0.60≤32.54.0±0.3015
35KV WMPG 70/3570≥702.0±0.60≤35.04.0±0.3015
35KV WMPG 75/38*70/80≥752.0±0.60≤37.54.0±0.3015
35KV WMPG 80/4080/100≥802.0±0.60≤40.04.0±0.3015
35KV WMPG 100/50100/120≥1002.0±0.60≤50.04.0±0.3015
35KV WMPG 120/60150≥1202.0±0.60≤60.04.0±0.3015
35KV WMPG 150/75180≥1502.0±0.70≤75.04.0±0.3015
35KV WMPG 180/90*MAX≥1802.0±0.70≤90.04.0±0.3015
35KV WMPG 210/105*MAX≥2102.0±0.70≤105.04.0±0.3015
35KV WMPG 230/115*MAX≥2302.0±0.70≤115.04.0±0.3015
35KV WMPG 250/115*MAX≥2502.0±0.70≤125.04.0±0.3015

Remarks: There is no storage if the item is marked *. It should be especially customized.
Color: Standard color is red, yellow and green.

Contact 

35kv High Voltage Busbar Insulator; Optic Fiber Heat Shrink Tube

lily

I can speak in English and Russian.
Тел.:+86-755-2716 0885-810(Ext) 
Факс:+86-755-2716 0895
 
    

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours